Fluke 87V

65.20

The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment even in loud, high energy, and high altitude locations. A low pass filter supports accurate frequency measurements on VFDs and captures intermittents as fast 250 µS.

Use the 87V to measure AC current up to 10 A directly, or use an optional clamp for high current measurements.frequency to 200 kHz, plus % duty cycle, resistance, continuity and diode test. And it includes a built-in thermometer so you can take temperature readings without having to carry a separate instrument, and more. Plus, with its bright, two-level backlit display you’ll be able to see the results better in dim light.

Correctly measure pulse-width modulated motor drive signals

The Fluke 87V takes the guesswork out of drive system troubleshooting. It includes a unique function for accurately measuring noisy at the VFD and at the motor terminals. Special shielding blocks high frequency, high-energy noise generated by large drive systems.

SKU: VOBE-000045 Category:
Share

Description

SpecificationsVoltage DCMaximum voltage1000 VAccuracy±(0.05% + 1)Maximum resolution10 µVVoltage ACMaximum voltage1000 VAccuracy±(0.7% + 2) True RMSAC bandwidth20 kHz with low pass filter; 3 db @ 1 kHzMaximum resolution0.1 mVCurrent DCMaximum amps10 A (20 A for 30 seconds maximum)Amps accuracy±(0.2% + 2)Maximum resolution0.01 µACurrent ACMaximum amps10 A (20 A for 30 seconds maximum)Amps accuracy±(1.0% + 2) True RMSMaximum resolution0.1 µAResistanceMaximum resistance50 MΩAccuracy±(0.2% + 1)Maximum resolution0.1 ΩCapacitanceMaximum capacitance9,999 µFaccuracy±(1% + 2)Maximum resolution0.01 nFFrequencyMaximum frequency200 kHzAccuracy±(0.005% + 1)Maximum resolution0.01 HzDuty cycleMaximum duty cycle99.9%Accuracy±(0.2% per khz + 0.1%)Maximum resolution0.1%Temperature measurement–200.0 °C – 1090 °C
–328.0 °F – 1994.0 °F
excluding probe80 BK temperature probe–40.0 °C – 260 °C
–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greaterConductanceMaximum conductance60.00 nSAccuracy±(1.0% + 10)Maximum resolution0.01 nSDiodeRange3 VResolution1 mVAccuracy±(2% + 1)Duty cycle rangeAccuracyWithin ±(0.2% per kHz + 0.1%)Environmental SpecificationsOperating temperature–20 °C to + 55 °CStorage temperature–40 °C to + 60 °CHumidity (without condensation)0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)Operating Altitude2000 mSafety SpecificationsOvervoltage categoryEN 61010–1 to 1000 V CAT III, 600V CAT IVAgency approvalsUL, CSA, TÜV, VDE listedMechanical and General SpecificationsSize201 x 98 x 52 mm (with holster)Weight355 g
624 g – with holsterDisplayDigital6000 counts updates 4/sec.
19,999 counts in high–resolution modeAnalog32 segments, updates 40/secFrequency19,999 counts, updates 3/sec at > 10 HzWarrantyLifetimeBattery LifeAlkaline~400 hours typical, without backlightShock1 Meter drop per IEC 61010–1:2001VibrationPer MIL–PRF–28800 for a Class 2 instrument