{"id":23018,"date":"2019-01-04T23:47:17","date_gmt":"2019-01-04T23:47:17","guid":{"rendered":"https:\/\/vobe.eu\/product\/fluke-87v\/"},"modified":"2019-01-04T23:47:17","modified_gmt":"2019-01-04T23:47:17","slug":"fluke-87v","status":"publish","type":"product","link":"https:\/\/vobe.eu\/en\/product\/fluke-87v\/","title":{"rendered":"Fluke 87V"},"content":{"rendered":"<p>SpecificationsVoltage DC<strong>Maximum voltage<\/strong>1000 VAccuracy\u00b1(0.05% + 1)Maximum resolution10 \u00b5VVoltage AC<strong>Maximum voltage<\/strong>1000 VAccuracy\u00b1(0.7% + 2) True RMSAC bandwidth20 kHz with low pass filter; 3 db @ 1 kHzMaximum resolution0.1 mVCurrent DC<strong>Maximum amps<\/strong>10 A (20 A for 30 seconds maximum)Amps accuracy\u00b1(0.2% + 2)Maximum resolution0.01 \u00b5ACurrent AC<strong>Maximum amps<\/strong>10 A (20 A for 30 seconds maximum)Amps accuracy\u00b1(1.0% + 2) True RMSMaximum resolution0.1 \u00b5AResistance<strong>Maximum resistance<\/strong>50 M\u03a9Accuracy\u00b1(0.2% + 1)Maximum resolution0.1 \u03a9Capacitance<strong>Maximum capacitance<\/strong>9,999 \u00b5Faccuracy\u00b1(1% + 2)Maximum resolution0.01 nFFrequency<strong>Maximum frequency<\/strong>200 kHzAccuracy\u00b1(0.005% + 1)Maximum resolution0.01 HzDuty cycle<strong>Maximum duty cycle<\/strong>99.9%Accuracy\u00b1(0.2% per khz + 0.1%)Maximum resolution0.1%Temperature measurement\u2013200.0 \u00b0C \u2013 1090 \u00b0C<br \/>\n\u2013328.0 \u00b0F \u2013 1994.0 \u00b0F<br \/>\nexcluding probe80 BK temperature probe\u201340.0 \u00b0C \u2013 260 \u00b0C<br \/>\n\u201340.0 \u00b0F \u2013 500 \u00b0F, 2.2 \u00b0C or 2% whichever is greaterConductance<strong>Maximum conductance<\/strong>60.00 nSAccuracy\u00b1(1.0% + 10)Maximum resolution0.01 nSDiode<strong>Range<\/strong>3 VResolution1 mVAccuracy\u00b1(2% + 1)Duty cycle range<strong>Accuracy<\/strong>Within \u00b1(0.2% per kHz + 0.1%)Environmental SpecificationsOperating temperature\u201320 \u00b0C to + 55 \u00b0CStorage temperature\u201340 \u00b0C to + 60 \u00b0CHumidity (without condensation)0% \u2013 90% (0 \u00b0C \u2013 35 \u00b0C)<br \/>\n0% \u2013 70% (35 \u00b0C \u2013 55 \u00b0C)Operating Altitude2000 mSafety SpecificationsOvervoltage categoryEN 61010\u20131 to 1000 V CAT III, 600V CAT IVAgency approvalsUL, CSA, T\u00dcV, VDE listedMechanical and General SpecificationsSize201 x 98 x 52 mm (with holster)Weight355 g<br \/>\n624 g \u2013 with holsterDisplay<strong>Digital<\/strong>6000 counts updates 4\/sec.<br \/>\n19,999 counts in high\u2013resolution modeAnalog32 segments, updates 40\/secFrequency19,999 counts, updates 3\/sec at &gt; 10 HzWarrantyLifetimeBattery Life<strong>Alkaline<\/strong>~400 hours typical, without backlightShock1 Meter drop per IEC 61010\u20131:2001VibrationPer MIL\u2013PRF\u201328800 for a Class 2 instrument<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment even in loud, high energy, and high altitude locations. A low pass filter supports accurate frequency measurements on VFDs and captures intermittents as fast 250 \u00b5S.<\/p>\n<p>Use the 87V to measure AC current up to 10 A directly, or use an optional clamp for high current measurements.frequency to 200 kHz, plus % duty cycle, resistance, continuity and diode test. And it includes a built-in thermometer so you can take temperature readings without having to carry a separate instrument, and more. Plus, with its bright, two-level backlit display you\u2019ll be able to see the results better in dim light.<\/p>\n<p><strong>Correctly measure pulse-width modulated motor drive signals<\/strong><\/p>\n<p>The Fluke 87V takes the guesswork out of drive system troubleshooting. It includes a unique function for accurately measuring noisy at the VFD and at the motor terminals. Special shielding blocks high frequency, high-energy noise generated by large drive systems.<\/p>\n","protected":false},"featured_media":22593,"template":"","meta":{"_acf_changed":false},"product_cat":[213],"product_tag":[],"class_list":{"0":"post-23018","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-fluke-en","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/product\/23018"}],"collection":[{"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/media\/22593"}],"wp:attachment":[{"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/media?parent=23018"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/product_cat?post=23018"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/product_tag?post=23018"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}