{"id":18284,"date":"2017-01-22T23:12:20","date_gmt":"2017-01-22T23:12:20","guid":{"rendered":"http:\/\/vobe.eu\/product\/field-metrology-well-model-9142-9143-2\/"},"modified":"2018-04-27T01:22:09","modified_gmt":"2018-04-27T01:22:09","slug":"field-metrology-well-model-9142-9143-2","status":"publish","type":"product","link":"https:\/\/vobe.eu\/en\/product\/field-metrology-well-model-9142-9143-2\/","title":{"rendered":"Field metrology well Model 9142"},"content":{"rendered":"<table>\n<tbody>\n<tr>\n<td colspan=\"2\">Base Unit Specifications<\/td>\n<\/tr>\n<tr>\n<td>Temperature range at 23\u00b0C<\/td>\n<td>33\u00b0C to 350\u00b0C (91\u00b0F to 662\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td>Display accuracy<\/td>\n<td>\u00b10.2\u00b0C Full Range<\/td>\n<\/tr>\n<tr>\n<td>Stability<\/td>\n<td>\u00b10.02\u00b0C at 33\u00b0C<br \/>\n\u00b10.02\u00b0C at 200\u00b0C<br \/>\n\u00b10.03\u00b0C at 350\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Axial uniformity at 40 mm (1.6 in)<\/td>\n<td>\u00b10.04\u00b0C at 33\u00b0C<br \/>\n\u00b10.1\u00b0C at 200\u00b0C<br \/>\n\u00b10.2\u00b0C at 350\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Radial uniformity<\/td>\n<td>\u00b10.01\u00b0C at 33\u00b0C<br \/>\n\u00b10.015\u00b0C at 200\u00b0C<br \/>\n\u00b10.02\u00b0C at 350\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)<\/td>\n<td>\u00b10.015\u00b0C Full Range<\/td>\n<\/tr>\n<tr>\n<td>Hysteresis<\/td>\n<td>0.03<\/td>\n<\/tr>\n<tr>\n<td>Operating conditions<\/td>\n<td>0\u00b0C to 50\u00b0C, 0% to 90% RH (non-condensing)<\/td>\n<\/tr>\n<tr>\n<td>Environmental conditions (for all specifications except temperature range)<\/td>\n<td>13\u00b0C to 33\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Immersion (well) depth<\/td>\n<td>150 mm (5.9 in)<\/td>\n<\/tr>\n<tr>\n<td>Insert OD<\/td>\n<td>25.3 mm (1.00 in)<\/td>\n<\/tr>\n<tr>\n<td>Heating time<\/td>\n<td>5 min: 33\u00b0C to 350\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Cooling time<\/td>\n<td>32 min: 350\u00b0C to 33\u00b0C<br \/>\n14 min: 350\u00b0C to 100\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.01\u00b0<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>LCD, \u00b0C or \u00b0F user-selectable<\/td>\n<\/tr>\n<tr>\n<td>Size (H x W x D)<\/td>\n<td>290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>7.3 kg (16 lb)<\/td>\n<\/tr>\n<tr>\n<td>Power requirements<\/td>\n<td>100 V to 115 V (\u00b110%), 50\/60 Hz, 1400 W 230 V (\u00b110%), 50\/60 Hz, 1800 W<\/td>\n<\/tr>\n<tr>\n<td>Computer interface<\/td>\n<td>RS-232 and 9930 Interface-<i>it<\/i>\u00a0control software included<\/td>\n<\/tr>\n<tr class=\"head\">\n<td colspan=\"2\">-P specifications<\/td>\n<\/tr>\n<tr>\n<td>Built-in reference thermometer readout accuracy (4-Wire reference probe)<sup>1<\/sup><\/td>\n<td>\u00b10.010\u00b0C at -25\u00b0C<br \/>\n\u00b10.015\u00b0C at 0\u00b0C<br \/>\n\u00b10.020\u00b0C at 50\u00b0C<br \/>\n\u00b10.025\u00b0C at 150\u00b0C<br \/>\n\u00b10.030\u00b0C at 200\u00b0C<br \/>\n\u00b10.040\u00b0C at 350\u00b0C<br \/>\n\u00b10.050\u00b0C at 420\u00b0C<br \/>\n\u00b10.070\u00b0C at 660\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Reference resistance range<\/td>\n<td>0 ohms to 400 ohms<\/td>\n<\/tr>\n<tr>\n<td>Reference resistance accuracy<sup>2<\/sup><\/td>\n<td>0 ohms to 42 ohms: \u00b10.0025 ohms 42 ohms to 400 ohms: \u00b160 ppm of reading<\/td>\n<\/tr>\n<tr>\n<td>Reference characterizations<\/td>\n<td>ITS-90, CVD, IEC-751, Resistance<\/td>\n<\/tr>\n<tr>\n<td>Reference measurement capability<\/td>\n<td>4-wire<\/td>\n<\/tr>\n<tr>\n<td>Reference probe connection<\/td>\n<td>6-pin Din with Infocon Technology<\/td>\n<\/tr>\n<tr>\n<td>Built-in RTD thermometer readout accuracy<\/td>\n<td>NI-120: \u00b10.015\u00b0C at 0\u00b0C<br \/>\nPT-100 (385): \u00b10.02\u00b0C at 0\u00b0C<br \/>\nPT-100 (3926): \u00b10.02\u00b0C at 0\u00b0C<br \/>\nPT-100 (JIS): \u00b10.02\u00b0C at 0\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>RTD resistance range<\/td>\n<td>0 ohms to 400 ohms<\/td>\n<\/tr>\n<tr>\n<td>RTD resistance accuracy\u2021<\/td>\n<td>0 ohms to 25 ohms: \u00b10.002 ohms<br \/>\n25 ohms to 400 ohms: \u00b180 ppm of reading<\/td>\n<\/tr>\n<tr>\n<td>RTD characterizations<\/td>\n<td>\u00a0PT-100 (385),(JIS),(3926), NI-120, Resistance<\/td>\n<\/tr>\n<tr>\n<td>RTD measurement capability<\/td>\n<td>4-wire RTD (2-,3-wire RTD w Jumpers only)<\/td>\n<\/tr>\n<tr>\n<td>RTD connection<\/td>\n<td>4 terminal input<\/td>\n<\/tr>\n<tr>\n<td>Built-in TC thermometer readout accuracy<\/td>\n<td>Type J: \u00b10.7\u00b0C at 660\u00b0C<br \/>\nType K: \u00b10.8\u00b0C at 660\u00b0C<br \/>\nType T: \u00b10.8\u00b0C at 400\u00b0C<br \/>\nType E: \u00b10.7\u00b0C at 660\u00b0C<br \/>\nType R: \u00b11.4\u00b0C at 660\u00b0C<br \/>\nType S: \u00b11.5\u00b0C at 660\u00b0C<br \/>\nType M: \u00b11.4\u00b0C at 660\u00b0C<br \/>\nType L: \u00b10.7\u00b0C at 660\u00b0C<br \/>\nType U: \u00b10.75\u00b0C at 600\u00b0C<br \/>\nType N: \u00b10.9\u00b0C at 660\u00b0C<br \/>\nType C: \u00b11.1\u00b0C at 660\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>TC millivolt range<\/td>\n<td>\u201310 mV to 75 mV<\/td>\n<\/tr>\n<tr>\n<td>Voltage accuracy<\/td>\n<td>0.025% of reading + 0.01 mV<\/td>\n<\/tr>\n<tr>\n<td>Internal cold junction compensation accuracy<\/td>\n<td>\u00b10.35\u00b0C (ambient of 13\u00b0C to 33\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td>TC connection<\/td>\n<td>Small connectors<\/td>\n<\/tr>\n<tr>\n<td>Built-in mA readout accuracy<\/td>\n<td>0.02% of reading + 2 mV<\/td>\n<\/tr>\n<tr>\n<td>mA range<\/td>\n<td>Cal 4-22 mA, Spec 4-24 mA<\/td>\n<\/tr>\n<tr>\n<td>mA connection<\/td>\n<td>2 terminal input<\/td>\n<\/tr>\n<tr>\n<td>Loop power function<\/td>\n<td>24 V DC loop power<\/td>\n<\/tr>\n<tr>\n<td>Built-in electronics temperature coefficient (0\u00b0C to 13\u00b0C, 33\u00b0C to 50\u00b0C)<\/td>\n<td>\u00b10.005% of range per \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The new 9142 and 9143 Series Field Metrology Wells extend high performance of the industrial process environment by maximizing portability, speed, and functionality with little compromise metrology performance. Field Metrology Wells are packed with functionality and are remarkably easy to use. They are light in weight, to achieve small and quickly to temperature setpoints, but they are stable, uniform and accurate. This industri ?? le temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the option &#8220;process&#8221;, there is no need to be carried along additional tools. This optional built-in two-channel readout reads resistance, voltage, and 4-20 mA current with 24 volt line. It also has on-board automation and documentation.<\/p>\n","protected":false},"featured_media":18185,"template":"","meta":{"_acf_changed":false},"product_cat":[176],"product_tag":[179],"class_list":{"0":"post-18284","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-vobe-en","7":"product_tag-fluke-en","8":"pa_brand-fluke-en","10":"first","11":"instock","12":"purchasable","13":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/product\/18284"}],"collection":[{"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/media\/18185"}],"wp:attachment":[{"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/media?parent=18284"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/product_cat?post=18284"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/vobe.eu\/en\/wp-json\/wp\/v2\/product_tag?post=18284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}